Инд. авторы: Dudnikov V., Johnson R.P., Han B., Murray S., Pennisi T., Piller C., Santana M., Stockli M., Welton R., Breitschopf J., Dudnikova G.
Заглавие: Ion Extraction from a Saddle Antenna RF Surface Plasma Source
Библ. ссылка: Dudnikov V., Johnson R.P., Han B., Murray S., Pennisi T., Piller C., Santana M., Stockli M., Welton R., Breitschopf J., Dudnikova G. Ion Extraction from a Saddle Antenna RF Surface Plasma Source // Fourth International Symposium on Negative Ions, Beams and Sources (NIBS 2014). - 2015. - Vol.1655. - Art.070003. - ISBN 978-0-7354-1297-2. - ISSN 0094-243X.
Внешние системы: DOI: 10.1063/1.4916483; SCOPUS: 2-s2.0-85030105937; WoS: 000362295300075;
Реферат: eng: Existing RF Surface Plasma Sources (SPS) for accelerators have specific efficiencies for H+ and H- ion generation around 3 to 5 mA/cm(2) per kW, where about 50 kW of RF power is typically needed for 50 mA beam current production. The Saddle Antenna (SA) SPS described here was developed to improve H- ion production efficiency and SPS reliability and availability. At low RF power, the efficiency of positive ion generation in the plasma has been improved to 200 mA/cm2 per kW of RF power at 13.56 MHz. Initial cesiation of the SPS was performed by heating cesium chromate cartridges by discharge as was done in the very first versions of the SPS. A small oven to decompose cesium compounds and alloys was developed and tested. After cesiation, the current of negative ions to the collector was increased from 1 mA to 10 mA with RF power similar to 1.5 kW in the plasma (6 mm diameter emission aperture) and up to 30 mA with similar to 4 kW RF power in the plasma and 250 Gauss longitudinal magnetic field. The ratio of electron current to negative ion current was improved from 30 to 2. Stable generation of H- beam without intensity degradation was demonstrated in the AlN discharge chamber for a long time at high discharge power in an RF SPS with an external antenna. Continuous wave (CW) operation of the SA SPS has been tested on the small test stand. The general design of the CW SA SPS is based on the pulsed version. Some modifications were made to improve the cooling and cesiation stability. The extracted collector current can be increased significantly by optimizing the longitudinal magnetic field in the discharge chamber. CW operation with negative ion extraction was tested with RF power up to 1.8 kW from the generator (similar to 1.2 kW in the plasma) with production up to Ic=7 mA. Long term operation was tested with 1.2 kW from the RF generator (similar to 0.8 kW in the plasma) with production of Ic=5 mA, Iex similar to 15 mA (Uex=8 kV, Uc=14 kV).
Издано: 2015
Физ. характеристика: 070003
Конференция: Название: 4th International Symposium on Negative Ions, Beams and Sources
Аббревиатура: NIBS-2014
Город: Garching
Страна: Germany
Даты проведения: 2014-10-06 - 2014-10-10