Инд. авторы: Lavrentev Y.G., Karmanov N.S., Usova L.V.
Заглавие: Electron probe microanalysis of minerals: microanalyzer or scanning electron microscope?
Библ. ссылка: Lavrentev Y.G., Karmanov N.S., Usova L.V. Electron probe microanalysis of minerals: microanalyzer or scanning electron microscope? // Russian Geology and Geophysics. - 2015. - Vol.56. - Iss. 8. - P.1154-1161. - ISSN 1068-7971. - EISSN 1878-030X.
Внешние системы: DOI: 10.1016/j.rgg.2015.07.006; РИНЦ: 23996649; SCOPUS: 2-s2.0-84938771469; WoS: 000359363000006;
Реферат: eng: The results of electron probe microanalysis of several rock-forming minerals by wavelength-dispersive spectrometry (WDS) and energy-dispersive spectrometry (EDS) are compared, and the metrological characteristics of both methods are studied. The measurements were made with the use of a JXA-8100 (JEOL) microanalyzer with five wavelength-dispersive spectrometers and a MIRA 3 LMU (Tescan) scanning electron microscope equipped with an INCA Energy 450 XMax 80 (Oxford Instruments) microanalysis system. Specimens with olivine, garnet, pyroxene, ilmenite, and Cr-spinel grains were analyzed. The variation coefficients that characterize the repeatability of a single determination are found to be similar to 0.5% for WDS and similar to 0.9% for EDS in the compositional range of the main components (C > 10%). For minor components (1% < C < 10%), the variation coefficients are 1.4% and 3.0%, respectively, and for impurities (0.3% < C < 1%), 2.7% and 13%, respectively. For lower contents EDS is almost inapplicable. The ratio of the results obtained by the two methods is reproduced with high precision: For major components, the variation coefficient is 0.56%; for minor components, 1.7%; and even for impurities, it is similar to 8%. The magnitude of the bias is between 0.2 and 3.2 rel.%, which is acceptable. The results show that the accuracies of WDS and EDS are similar for measuring major and minor components of rock-forming minerals. Energy-dispersive spectrometry is inferior to wavelength-dispersive spectrometry for impurities and is completely inapplicable for still lower contents. This method is easier to implement, and the results are available soon after switching on the instrument. Wavelength-dispersive spectrometry needs more time for preparation, but it ensures a precise high-efficiency large-scale analysis of samples of similar compositions, even when the element contents are lower than 1%. (C) 2015, V.S. Sobolev IGM, Siberian Branch of the RAS. Published by Elsevier B.V. All rights reserved.
Ключевые слова: rock-forming minerals; metrological characteristics; ACCURACY; wavelength-dispersive spectrometry; electron probe microanalysis; energy-dispersive spectrometry;
Издано: 2015
Физ. характеристика: с.1154-1161